Author Archives: [email protected]

  • Microbially Induced Corrosion: Coating Failures in Water-Immersion Conditions

    Broadly speaking, industrial coatings used in water-immersion conditions fail due to the following: Osmotic Blistering, Microbially Induced Corrosion (MIC), and Poor Surface Preparation and Application. In our previous blog post, we explored Osmotic Blistering as a common cause of coating failure in water-immersion conditions. This blog post explains how microbiologically influenced corrosion impacts the protective [...] More
  • Coating Failures in Water-Immersion Conditions: Osmotic Blistering

    Water-immersion conditions are found in a variety of industrial applications. Circulating water systems, tanks and other critical infrastructure made of metallic substrates are typically protected from corrosion by immersion-grade coatings designed to act as barriers to prevent corrosion. For asset owners and maintenance staff, the ability of coatings to provide continued protection from corrosion or [...] More