Three vertical pipes with composite pipe repair wrapped around them.

Composite Pipe Repair

Industry: Power Transmission

Solution: Pipe-Type Cables - HPFF

ID: CPR-5-00135

Project summary:

Inspectors at an urban utility company discovered external corrosion on several hundred feet of high-pressure, fluid filled, pipe-type cables as they extended into a tunnel. The vertical runs of piping required extensive scaffolding for proper access and several pipes were located in close proximity. Advanced FRP provided a solution that would protect all the pipes in the area with a high-strength, carbon fiber based composite system. The repair system was designed to handle up to 1,000 psi of internal pressure and would provide a 50-year life extension for these critical assets.

  • Date of installation: 08/22
  • Facility/Location: New York
  • Applicator: CTI
  • Products used:
  • FRP Repair Putty
  • FRP 120 HT Adhesive
  • FRP 210 HT Saturant
  • GF-300 BD
  • CF-500 BD
  • HP 300 Epoxy

BACK